Installation of water and warm construction is the key

Floor heating is known as the "three-point product seven-point installation," said the importance of warm installation. In order to enable more people to enjoy the spring-like comfort brought by the warmth of the ground in the cold winter, Shanghai Yimei has simply listed the specifications for floor heating to ensure the quality of the floor heating system.

The pros and cons of water floor heating construction determine the feelings of the customers after use. The poor construction will make you fret, and the high-quality construction will make you comfortable and comfortable.

Detailed floor heating design: Construction personnel strictly follow HVAC designer's "floor heating design" construction to prevent construction workers from arbitrarily constructing, and avoid the hidden dangers of floor heating from the source.

No floor heating plan: no detailed map of floor heating, only diagonal lines are used to indicate that there is floor heating in this area, which easily leads to casual construction by construction workers, thus creating a huge hidden danger for the floor heating system.

Detailed boiler positioning map: Each boiler has a detailed and accurate positioning dimension map, which can ensure the accurate installation of the boiler in the later period, and effectively avoid a series of problems caused by the boiler position error.

No-size boiler positioning map: No specific size of the positioning map will result in inaccurate positioning of the boiler in the later period. As a result, the boiler has insufficient space for installation and the flue can not be properly installed, causing the boiler exhaust gas to be discharged to the outdoors.

The use of back-folding type laying: The back-flush floor heating pipe laying is the best laying method for floor heating. It is more uniform in heating and higher in comfort. It is the first choice in laying floor heating.

Parallel-type laying: Parallel-type laying will lead to uneven heating and heating, and the floor heating pipe needs to be bent 180 degrees, resulting in increased resistance to water flow, which seriously affects the heating effect and heating comfort.

  

The spacing between floor heating pipes is uniform: we strive to keep all the floor heating intervals uniform and uniform: the spacing of floor heating pipes in the floor tiles is not more than 18cm; the floor heating floor spacing is not more than 15cm, which is more conducive to uniform heat distribution and higher comfort.

Unequal spacing between floor heating pipes: Uneven heating floor spacing is not evenly distributed, which can lead to local thermal or local overheating, and heating comfort. The resulting problems are irreversible.

Floor heating pipe is more than 10cm away from the wall: all floor heating pipes are at least 10cm away from the wall, which can effectively avoid unnecessary heat loss.

The “zero” distance from the wall of the floor heating pipe: Too close to the wall of the floor heating pipe will cause heat loss and increase unnecessary energy expenditure.

Villa design nature floor space floor tiles

Brandt BLT-50/LCM-2D Shaker Screen

Replacement Flat Screens for Brandt BLT-50/LCM-2D Shakers

SJ-Brandt BLT-50 /LCM-2D shaker screen are constructed with two or three layers of 304 or 316 stainless steel wire mesh cloth, and then combined together with a steel backing plate. This type of shaker screen is produced for the replacement screen for Brandt BLT-50/LCM-2D (bottom basket) shale shaker. Mesh size range is from API 20 to API 325. The screens vary greatly in size and shape for different layers. Thus, the intensity and endurance of the screen have been infinitely enhanced, so as to achieve maximum solids removal efficiency.

Technical Parameter

  • Mesh Material: stainless steel 304/316/316 L.
  • Frame Material: Q235 steel.
  • Screen Type: XL, XR.
  • API RP 13C Designation: API 20–API 325.
  • Package: Packed in paper carton, shipped by wooden case.

Adaptable Shale Shaker Model

SJ-Brandt BLT-50 /LCM-2D shaker screen are used as the substitute screen for

  • Brandt BLT-50 shale shaker.
  • Brandt LCM-2D shale shaker.

Competitive Advantage

  • Reliable, low-maintenance, trouble-free operation.
  • Specialty design for maximum solids removal efficiency.
  • Integrated drying screen for fine screen deck.
  • Manufactured according to the API RP 13C (ISO 13501).
  • Scientific & reasonable cost control system for competitive price.
  • Adequate inventory in the shortest time to meet customers' demand.
Brandt BLT-50 Shaker Screen

Remarks:

Brandt, BLT-50, LCM-2D are marks of Varco I/P, Inc.

ShengJia only produces the replacement screens but not original from Brandt.

Brandt BLT-50 Shaker ScreenBrandt BLT-50 Shaker Screen


Brandt BLT-50 Shaker Screen

Brandt Blt-50 Shaker Screen,Brandt Blt-50/Lcm-2D Shaker Screen,Brandt Blt-50/Lcm-2D Shale Shaker Screen,Brandt Blt-50/Lcm-2Doil Shale Shaker Screen

Anping Shengjia Hardware Mesh Co.,ltd , https://www.oilshakerscreen.com